Automatic identification.
Built for rail.
Sentinel Inspection Systems supplies, specifies and supports TransCore® MPRX RFID readers for Australian rail networks — reliable, rugged automatic identification of locomotives, railcars and rail assets, on the wayside and onboard.
Which MPRX configuration fits the job?
Start with where the reader will operate. The application determines the reader configuration, antenna arrangement and final installation details.
Knowing what's on the network, automatically.
Manual identification of railcars, locomotives and intermodal assets is slow and error-prone. RFID gives rail operators, yards and maintenance facilities a reliable, automatic record of what moved where — without adding steps to day-to-day operations.
Railcar & locomotive ID
Positive identification of railcars and locomotives for accurate tracking, reporting and fleet visibility.
Intermodal & yard operations
Streamline container and chassis tracking at intermodal terminals, and improve yard visibility with automated asset identification.
Maintenance & fuel tracks
Support maintenance workflows with reliable asset history, and secure fuelling operations with positive asset identification.
Wayside and onboard. One reader platform.
The TransCore® MPRX range delivers best-in-class read range and accuracy in a compact, rugged design — purpose-built for the toughest rail environments. Choose a multi-antenna wayside reader for trackside gantries, or a single-port onboard reader for fitment to a locomotive or rail vehicle.
MPRX Four Port Wayside RFID Reader
Model 10-7210-001
Delivers best-in-class read range and accuracy in a compact, rugged design. Purpose-built for wayside applications, providing reliable automatic identification of railcars, locomotives and assets from trackside gantry installations.
- Four port reader — up to four multiplexed antenna connections
- Reads all major UHF RFID tags, including AAR-formatted tags
- Full-frame & half-frame tag support via Super eGo® (SeGo)
- Ethernet (10/100), RS-422 and RS-232 communications
- Wayside +12–110 VDC power input
- IP65/67 rated enclosure, −40°C to +70°C operating range
MPRX Single Port Onboard RFID Reader
Model 10-7200-002
Delivers best-in-class read range and accuracy in a compact, rugged design. Purpose-built for onboard rail applications, providing reliable automatic identification in the harshest onboard environments.
- Single port reader — dependable single-antenna performance
- Reads all major UHF RFID tags, including AAR-formatted tags
- Full-frame & half-frame tag support via Super eGo® (SeGo)
- Ethernet (10/100), RS-422 and RS-232 communications
- Onboard +12–110 VDC (+24–110 VDC EN50155) power input
- IP65/67 rated enclosure, −40°C to +70°C operating range
MPRX Four Port vs MPRX Single Port.
Full specifications are confirmed against your application during technical assessment. Read range depends on tag type, antenna configuration and environment.
| Specification | MPRX Four Port (Wayside) | MPRX Single Port (Onboard) |
|---|---|---|
| Model | 10-7210-001 | 10-7200-002 |
| Antenna ports | 4 (multiplexed) | 1 |
| Frequency | 902–928 MHz (fixed) | 902–928 MHz (fixed) |
| Protocols | ATA (ISO 10374), Super eGo® (SeGo), eGo (ISO 18000-6B), IAG | ATA (ISO 10374), Super eGo® (SeGo), eGo (ISO 18000-6B), IAG |
| Typical read range | 3.7–5.2 m (12–17 ft)* | 3.7–5.2 m (12–17 ft)* |
| Communications | Ethernet (10/100), RS-422, RS-232 | Ethernet (10/100), RS-422, RS-232 |
| Input power | +12–110 VDC (wayside) | +12–110 VDC (+24–110 VDC EN50155) |
| RF output power | 17–32 dBm (adjustable in 1 dB steps) | 17–32 dBm (adjustable in 1 dB steps) |
| Enclosure | IP65/67 rated with appropriate connectors | IP65/67 rated with appropriate connectors |
| Operating temperature | −40°C to +70°C | −40°C to +70°C |
| Dimensions (L×W×H) | 33 × 7.62 × 6.32 cm (13 × 5 × 2.49 in) | 33 × 7.62 × 6.32 cm (13 × 5 × 2.49 in) |
| Weight | 2.6 kg (5.7 lb) | 2.6 kg (5.7 lb) |
| AU compliance | ACMA-compliant firmware available† | ACMA-compliant firmware available† |
*Read range depends on tag type, antenna configuration and environment.
†ACMA compliance is a firmware configuration, not a fixed property of the hardware — both MPRX models are available with or without ACMA-compliant firmware loaded. Confirm the firmware/compliance status you need at time of order.
Beyond MPRX: SmartPass & Encompass.
MPRX is Sentinel's core rail RFID platform — purpose-built for wayside and onboard rail applications, and the range detailed on this page. TransCore's broader RFID reader portfolio also includes the SmartPass and Encompass (E4) families, which can be configured for rail-adjacent identification and asset-tracking applications. If your project calls for one of these, talk to us — availability and ACMA-compliant firmware are confirmed per model and order.
MPRX rail reader range
Sentinel's core rail RFID platform. Four Port Wayside (10-7210-001) and Single Port Onboard (10-7200-002), both available with ACMA-compliant firmware. Full specifications above.
TransCore SmartPass
Available in multiple variants. Models 10-4004-011 (RS-422) and 10-4002-008 (RS-232) are available with or without ACMA-compliant firmware — confirm the firmware/compliance status you need at order. Model 10-4004-008 (RS-422) is not held in stock and is only imported on specific request.
TransCore Encompass (E4)
Part of TransCore's wider RFID reader family. Enquire for current availability and ACMA-compliant firmware status for your application.
ACMA compliance is a firmware configuration confirmed per unit at the time of order — it is not an inherent, fixed property of a hardware model. Model numbers and stock/import status shown are as supplied to Sentinel Inspection Systems and are subject to change — always confirm current ACMA compliance status for the specific model and firmware before specifying it for an Australian network.
MPRX reader + antennas + RFID tags + software.
Combine the MPRX Wayside or Onboard reader with TransCore® antennas, AAR-formatted RFID tags and software for a complete, future-ready RFID identification solution — specified around your fleet and network.
Where wayside & onboard RFID is used.
Railcar identification
Positive identification of railcars for accurate tracking and reporting.
Locomotive identification
Automatically identifies locomotives for operational visibility and safety.
Intermodal operations
Streamline container and chassis tracking in intermodal terminals.
Yard management
Improve yard visibility and efficiency with automated asset identification.
Maintenance facilities
Support maintenance workflows with reliable asset identification and history.
Fuel tracks
Secure and automate fuelling operations with positive asset identification.
RFID, answered.
What is the read range of the MPRX RFID reader range?
Typical read range is approximately 3.7–5.2 m (12–17 ft), depending on tag type, antenna configuration and the environment. Final performance is confirmed during technical assessment.
What RFID protocols does the MPRX reader support?
The MPRX range reads AAR-formatted tags and supports ATA (ISO 10374), TransCore Super eGo® (SeGo), eGo (ISO 18000-6B) and IAG protocols, covering full-frame and half-frame tags.
What is the difference between the MPRX Four Port and MPRX Single Port readers?
The MPRX Four Port (10-7210-001) is a wayside reader supporting up to four multiplexed antenna connections for trackside gantry installations. The MPRX Single Port (10-7200-002) is an onboard reader with a single antenna port, designed for fitment to a locomotive or rail vehicle.
Is the MPRX RFID reader ACMA compliant for use in Australia?
Both the MPRX Four Port and MPRX Single Port readers are available with ACMA-compliant firmware for Australian deployment. Compliance is a firmware configuration rather than a fixed property of the hardware, so confirm the firmware/compliance status you need at the time of order.
Does TransCore offer other RFID readers besides MPRX?
Yes. TransCore's broader RFID reader portfolio includes the SmartPass and Encompass (E4) families in addition to the rail-specific MPRX range. MPRX remains Sentinel's core rail platform — talk to us if your project needs one of the other families.
Are all TransCore RFID readers ACMA compliant for use in Australia?
Not automatically — ACMA compliance depends on the firmware loaded on the specific unit, not the product family or model as a whole. Within the SmartPass range, for example, Models 10-4004-011 and 10-4002-008 are available with or without ACMA-compliant firmware, while Model 10-4004-008 is not held in stock and is only imported on specific request. Always confirm current ACMA compliance status for the exact model and firmware before specifying it for an Australian network.
Can RFID identification be combined with Sentinel's 360° vision system?
Yes. Vision and RFID identification are commonly specified together across the same rail fleet — see how the two connect on the rail overview page.
Let's specify RFID around your rail assets.
Tell us about your locomotives, railcars, yards or intermodal terminals, and we'll help define the right wayside or onboard RFID configuration.